Titler Live offers powerful integrations that communicate with Blackmagic Design’s ATEM switchers and their Software Control Application. This article describes how to set up your switcher so that Titler Live communicates with it properly.
ATEM Software Control
Blackmagic Designs ATEM Software Control Application must be downloaded and installed.
Click here to find the latest version of the Application. The software will be listed as "ATEM Switchers".
Setting up your ATEM
Titler Live communicates with the ATEM Software Control Application in order to capture/control stills and synchronizing transitions. Below are two different methods of connection that need to be established.
Connecting to PC with USB
The ATEM switcher requires a USB to USB-C cable to connect and access the Software Control Application on your PC. Titler Live also relies on this connection so that it can communicate with your ATEM.
Follow these steps to connect your ATEM switcher to your PC and to confirm this connection through ATEM Software Control and Titler Live.
- Connect the USB-C end to the ATEM’s Webcam Out port. Connect the opposite end into your PC that is running Titler Live and ATEM Software Control.
- To confirm this connection from ATEM Software Control, open the application. The switcher interface will automatically display if your ATEM device has been successfully recognized.
Click to File in the top left corner of the window and select Connection to open the ATEM Setup window. This Window allows you to preview your connection or manually configure it if the device is not automatically recognized. Click on ATEM Setup to preview the type of connection.
- Close ATEM Software Control and Launch Titler Live.
- Click on Settings to access the ATEM Settings.
- From this menu enable Sync to ATEM. The IP address and ATEM model will auto populate.
- Click on Connect
- Click OK to confirm the settings.
Connecting to Local Network with Ethernet
A different method to have Titler Live communicate with the ATEM Software Control’s API, the ATEM can be connected to a local network via ethernet cable.
There are two ways to accomplish this:
Connecting to Local Network via Broadband Router
- Connect one end of the ethernet cable into the ATEM’s ATEM Control port. Connect the opposite end to the Ethernet Port of your Broadband Router.
- Open your ATEM Software Control Application to confirm this connection.
- To confirm this connection from ATEM Software Control, open the application. The switcher interface will automatically display if your ATEM device has been successfully recognized.
Connecting to Local Network via PC
- Connect one end of the ethernet cable into the ATEM’s ATEM Control port. Connect the opposite end to the Ethernet Port of the Personal Computer that is running Titler Live.
- Open your ATEM Software Control Application to confirm this connection.
- To confirm this connection from ATEM Software Control, open the application. The switcher interface will automatically display if your ATEM device has been successfully recognized.
Important! If the ATEM Software Control fails to recognize the connection, some extra setup may be required. Follow these steps to manually set it up:
- Click on your network icon from your Taskbar
- Select Network & Internet Settings
- Click on Ethernet
- Under Related Settings, Click on Change Adaptor Settings.
- Right click over Ethernet and select Properties.
- Navigate to Internet Protocol Version 4 (TCP/IPv4), Select this option and click Properties.
- Select Use this IP address and manually enter: “198.168.10.240”. Navigating to the next line will automatically populate Subnet Mask
- Click OK
- Open ATEM software control to confirm if the connection has been recognized